Au-Ag 折射率

Au-Ag 的光学常数 (n, k) 数据,涵盖 0.27 – 1.20 μm 波长范围。

波长范围 0.270 – 1.200 μm
数据点 931

关键波长处的光学常数

632.8 nm (He-Ne)
n = 0.0311
k = 3.9594
589.3 nm (Na-D)
n = 0.0287
k = 3.6168
532 nm
n = 0.0267
k = 3.1578

n, k 色散曲线

数据表(采样)

波长 (μm) n k
0.27001.278041.27504
0.29301.435821.05502
0.31601.004290.30997
0.33900.142670.93328
0.36200.065681.41977
0.38500.044211.74853
0.40800.034972.01839
0.43100.030342.25794
0.45400.027942.47920
0.47700.026792.68835
0.50000.026412.88893
0.52300.026543.08315
0.54600.027053.27250
0.56900.027843.45799
0.59200.028853.64038
0.61500.030053.82022
0.63800.031403.99792
0.66100.032894.17382
0.68400.034504.34818
0.70700.036224.52121
0.73000.038044.69309
0.75300.039964.86395
0.77600.041965.03391
0.79900.044065.20308
0.82200.046245.37153
0.84500.048505.53935
0.86800.050845.70659
0.89100.053265.87331
0.91400.055756.03956
0.93700.058326.20537
0.96000.060966.37079
0.98300.063686.53585
1.00600.066466.70057
1.02900.069326.86498
1.05200.072257.02912
1.07500.075257.19298
1.09800.078317.35660
1.12100.081457.51999
1.14400.084667.68317
1.16700.087937.84615
1.19000.091288.00895
1.20000.092758.07967

上表为采样数据(共 931 个数据点),点击"下载完整 CSV"获取全部数据。