Optical constants (n, k) of TaS2 (e), covering 0.30 – 1.69 μm wavelength range.
| Wavelength (μm) | n | k |
|---|---|---|
| 0.3000 | 1.51399 | 0.86518 |
| 0.3240 | 1.78139 | 1.25758 |
| 0.3480 | 2.16639 | 1.30651 |
| 0.3720 | 2.68031 | 1.15995 |
| 0.3960 | 2.82663 | 0.67178 |
| 0.4200 | 2.67241 | 0.38319 |
| 0.4440 | 2.50932 | 0.27463 |
| 0.4680 | 2.38404 | 0.24140 |
| 0.4920 | 2.28988 | 0.24207 |
| 0.5160 | 2.21804 | 0.25998 |
| 0.5400 | 2.16255 | 0.28785 |
| 0.5640 | 2.12021 | 0.32155 |
| 0.5880 | 2.08693 | 0.35746 |
| 0.6120 | 2.05932 | 0.39571 |
| 0.6360 | 2.03582 | 0.43687 |
| 0.6600 | 2.01557 | 0.48168 |
| 0.6840 | 1.99815 | 0.53110 |
| 0.7080 | 1.98367 | 0.58642 |
| 0.7320 | 1.97280 | 0.64919 |
| 0.7560 | 1.96712 | 0.72129 |
| 0.7800 | 1.96942 | 0.80468 |
| 0.8040 | 1.98431 | 0.90114 |
| 0.8280 | 2.01897 | 1.01138 |
| 0.8520 | 2.08422 | 1.13316 |
| 0.8760 | 2.19514 | 1.25633 |
| 0.9000 | 2.36361 | 1.35211 |
| 0.9240 | 2.56816 | 1.37713 |
| 0.9480 | 2.75185 | 1.32855 |
| 0.9720 | 2.89247 | 1.24557 |
| 0.9960 | 2.99859 | 1.14935 |
| 1.0500 | 3.13423 | 0.92182 |
| 1.1100 | 3.16932 | 0.71369 |
| 1.1700 | 3.15716 | 0.56922 |
| 1.2300 | 3.13521 | 0.46799 |
| 1.2900 | 3.11407 | 0.39171 |
| 1.3500 | 3.09514 | 0.32978 |
| 1.4100 | 3.07753 | 0.27668 |
| 1.4700 | 3.06005 | 0.22961 |
| 1.5300 | 3.04175 | 0.18731 |
| 1.5900 | 3.02202 | 0.14927 |
| 1.6500 | 3.00057 | 0.11545 |
| 1.6900 | 2.98530 | 0.09534 |
Sampled data (977 points total). Click "Download Full CSV" for complete data.
Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.