Optical constants (n, k) of TAC4(HOYA), covering 0.37 – 1.01 μm wavelength range.
| Wavelength (μm) | n | k |
|---|---|---|
| 0.3650 | 1.76975 | 0.00000 |
| 0.3780 | 1.76565 | 0.00000 |
| 0.3910 | 1.76199 | 0.00000 |
| 0.4039 | 1.75870 | 0.00000 |
| 0.4169 | 1.75574 | 0.00000 |
| 0.4299 | 1.75307 | 0.00000 |
| 0.4429 | 1.75065 | 0.00000 |
| 0.4559 | 1.74845 | 0.00000 |
| 0.4688 | 1.74644 | 0.00000 |
| 0.4818 | 1.74460 | 0.00000 |
| 0.4948 | 1.74291 | 0.00000 |
| 0.5078 | 1.74136 | 0.00000 |
| 0.5208 | 1.73993 | 0.00000 |
| 0.5337 | 1.73860 | 0.00000 |
| 0.5467 | 1.73736 | 0.00000 |
| 0.5597 | 1.73622 | 0.00000 |
| 0.5727 | 1.73514 | 0.00000 |
| 0.5857 | 1.73414 | 0.00000 |
| 0.5986 | 1.73320 | 0.00000 |
| 0.6116 | 1.73232 | 0.00000 |
| 0.6246 | 1.73149 | 0.00000 |
| 0.6376 | 1.73070 | 0.00000 |
| 0.6506 | 1.72996 | 0.00000 |
| 0.6635 | 1.72926 | 0.00000 |
| 0.6765 | 1.72859 | 0.00000 |
| 0.6895 | 1.72796 | 0.00000 |
| 0.7025 | 1.72736 | 0.00000 |
| 0.7155 | 1.72679 | 0.00000 |
| 0.7284 | 1.72624 | 0.00000 |
| 0.7414 | 1.72571 | 0.00000 |
| 0.7544 | 1.72521 | 0.00000 |
| 0.7674 | 1.72473 | 0.00000 |
| 0.7804 | 1.72427 | 0.00000 |
| 0.7933 | 1.72383 | 0.00000 |
| 0.8063 | 1.72340 | 0.00000 |
| 0.8193 | 1.72298 | 0.00000 |
| 0.8323 | 1.72259 | 0.00000 |
| 0.8452 | 1.72220 | 0.00000 |
| 0.8582 | 1.72183 | 0.00000 |
| 0.8712 | 1.72147 | 0.00000 |
| 0.8842 | 1.72112 | 0.00000 |
| 0.8972 | 1.72078 | 0.00000 |
| 0.9101 | 1.72044 | 0.00000 |
| 0.9231 | 1.72012 | 0.00000 |
| 0.9361 | 1.71981 | 0.00000 |
| 0.9491 | 1.71950 | 0.00000 |
| 0.9621 | 1.71920 | 0.00000 |
| 0.9750 | 1.71891 | 0.00000 |
| 0.9880 | 1.71862 | 0.00000 |
| 1.0010 | 1.71834 | 0.00000 |
| 1.0140 | 1.71807 | 0.00000 |
Sampled data (101 points total). Click "Download Full CSV" for complete data.
Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.