Si-Ge Refractive Index

Optical constants (n, k) of Si-Ge, covering 0.24 – 0.84 μm wavelength range.

Range 0.240 – 0.840 μm
Data Points 103

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 5.0550
k = 0.3470
589.3 nm (Na-D)
n = 5.3780
k = 0.5750
532 nm
n = 5.4530
k = 1.7090

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.24001.571003.17700
0.24401.579003.26500
0.24801.613003.36800
0.25201.672003.48400
0.25601.731003.61000
0.26001.809003.75000
0.26401.896003.89500
0.26802.015004.06700
0.27202.170004.25800
0.27602.394004.46300
0.28002.739004.65900
0.28403.211004.72300
0.28803.691004.57000
0.29203.994004.28100
0.29604.165003.98800
0.30004.233003.73900
0.30804.276003.37900
0.31604.284003.14400
0.32404.296002.97600
0.33204.306002.84700
0.34004.317002.74100
0.34804.336002.65400
0.35604.368002.57400
0.36404.402002.50500
0.37204.444002.42300
0.38004.476002.33800
0.38804.487002.24100
0.39604.482002.14900
0.40404.449002.08400
0.41204.423002.04900
0.42004.402002.03900
0.44004.421002.07700
0.46004.537002.12500
0.48004.749002.16700
0.50005.086002.10600
0.52005.362001.83700
0.54005.580001.56000
0.56005.686001.05400
0.58005.488000.68300
0.60005.287000.49500
0.62005.127000.38800
0.64004.995000.31800
0.66004.901000.26600
0.68004.810000.23000
0.70004.741000.20300
0.72004.671000.18100
0.74004.620000.16300
0.76004.579000.14400
0.78004.529000.13300
0.80004.494000.11900
0.82004.466000.11200
0.84004.425000.10200

Sampled data (103 points total). Click "Download Full CSV" for complete data.

Related Materials (Other)

Need to measure Si-Ge thin film thickness?

Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.