Optical constants (n, k) of PBM5(OHARA), covering 0.30 – 2.19 μm wavelength range.
| Wavelength (μm) | n | k |
|---|---|---|
| 0.3000 | 1.69233 | 0.00001 |
| 0.3420 | 1.65787 | 0.00000 |
| 0.3840 | 1.63848 | 0.00000 |
| 0.4260 | 1.62609 | 0.00000 |
| 0.4680 | 1.61754 | 0.00000 |
| 0.5100 | 1.61131 | 0.00000 |
| 0.5520 | 1.60659 | 0.00000 |
| 0.5940 | 1.60291 | 0.00000 |
| 0.6360 | 1.59997 | 0.00000 |
| 0.6780 | 1.59756 | 0.00000 |
| 0.7200 | 1.59556 | 0.00000 |
| 0.7620 | 1.59386 | 0.00000 |
| 0.8040 | 1.59240 | 0.00000 |
| 0.8460 | 1.59113 | 0.00000 |
| 0.8880 | 1.59000 | 0.00000 |
| 0.9300 | 1.58900 | 0.00000 |
| 0.9720 | 1.58808 | 0.00000 |
| 1.0140 | 1.58725 | 0.00000 |
| 1.0560 | 1.58648 | 0.00000 |
| 1.0980 | 1.58576 | 0.00000 |
| 1.1400 | 1.58508 | 0.00000 |
| 1.1820 | 1.58443 | 0.00000 |
| 1.2240 | 1.58382 | 0.00000 |
| 1.2660 | 1.58323 | 0.00000 |
| 1.3080 | 1.58265 | 0.00000 |
| 1.3500 | 1.58210 | 0.00000 |
| 1.3920 | 1.58155 | 0.00000 |
| 1.4340 | 1.58101 | 0.00000 |
| 1.4760 | 1.58048 | 0.00000 |
| 1.5180 | 1.57996 | 0.00000 |
| 1.5600 | 1.57944 | 0.00000 |
| 1.6020 | 1.57892 | 0.00000 |
| 1.6440 | 1.57840 | 0.00000 |
| 1.6860 | 1.57788 | 0.00000 |
| 1.7280 | 1.57736 | 0.00000 |
| 1.7700 | 1.57684 | 0.00000 |
| 1.8120 | 1.57632 | 0.00000 |
| 1.8540 | 1.57579 | 0.00000 |
| 1.8960 | 1.57526 | 0.00000 |
| 1.9380 | 1.57472 | 0.00000 |
| 1.9800 | 1.57418 | 0.00000 |
| 2.0220 | 1.57363 | 0.00000 |
| 2.0640 | 1.57308 | 0.00000 |
| 2.1060 | 1.57252 | 0.00000 |
| 2.1480 | 1.57195 | 0.00000 |
| 2.1900 | 1.57138 | 0.00000 |
Sampled data (91 points total). Click "Download Full CSV" for complete data.