IUV380W Refractive Index

Optical constants (n, k) of IUV380W, covering 0.20 – 2.00 μm wavelength range.

Range 0.200 – 2.000 μm
Data Points 1801

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 1.5274
k = 0.0001
589.3 nm (Na-D)
n = 1.5285
k = 0.0001
532 nm
n = 1.5313
k = 0.0001
1550 nm (Telecom)
n = 1.4971
k = 0.0001

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.20001.664750.00004
0.24501.594470.00007
0.29001.568060.00010
0.33501.554440.00001
0.38001.547360.00000
0.42501.540170.00010
0.47001.536670.00010
0.51501.532640.00007
0.56001.530120.00008
0.60501.528050.00011
0.65001.526370.00009
0.69501.523690.00006
0.74001.523460.00008
0.78501.522920.00012
0.83001.520920.00016
0.87501.507480.00026
0.92001.504760.00029
0.96501.507240.00021
1.01001.504520.00019
1.05501.507170.00017
1.10001.505770.00016
1.14501.506780.00015
1.19001.501870.00015
1.23501.502500.00015
1.28001.504130.00014
1.32501.500390.00014
1.37001.501410.00013
1.41501.502650.00013
1.46001.498980.00012
1.50501.498590.00012
1.55001.497110.00012
1.59501.498750.00012
1.64001.502190.00011
1.68501.496950.00011
1.73001.496790.00011
1.77501.493340.00012
1.82001.494830.00012
1.86501.492320.00012
1.91001.493180.00012
1.95501.492160.00012
2.00001.492710.00012

Sampled data (1801 points total). Click "Download Full CSV" for complete data.

Related Materials (Specs)

Need to measure IUV380W thin film thickness?

Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.