Optical constants (n, k) of H-ZLAF50D(CDGM), covering 0.36 – 2.19 μm wavelength range.
| Wavelength (μm) | n | k |
|---|---|---|
| 0.3650 | 1.84785 | 0.00000 |
| 0.4042 | 1.83394 | 0.00000 |
| 0.4434 | 1.82402 | 0.00000 |
| 0.4826 | 1.81665 | 0.00000 |
| 0.5218 | 1.81099 | 0.00000 |
| 0.5610 | 1.80652 | 0.00000 |
| 0.6002 | 1.80292 | 0.00000 |
| 0.6394 | 1.79994 | 0.00000 |
| 0.6786 | 1.79745 | 0.00000 |
| 0.7178 | 1.79533 | 0.00000 |
| 0.7570 | 1.79349 | 0.00000 |
| 0.7962 | 1.79188 | 0.00000 |
| 0.8354 | 1.79046 | 0.00000 |
| 0.8746 | 1.78918 | 0.00000 |
| 0.9138 | 1.78801 | 0.00000 |
| 0.9530 | 1.78695 | 0.00000 |
| 0.9922 | 1.78596 | 0.00000 |
| 1.0314 | 1.78503 | 0.00000 |
| 1.0706 | 1.78416 | 0.00000 |
| 1.1098 | 1.78334 | 0.00000 |
| 1.1490 | 1.78255 | 0.00000 |
| 1.1882 | 1.78179 | 0.00000 |
| 1.2274 | 1.78105 | 0.00000 |
| 1.2666 | 1.78033 | 0.00000 |
| 1.3058 | 1.77963 | 0.00000 |
| 1.3450 | 1.77894 | 0.00000 |
| 1.3842 | 1.77825 | 0.00000 |
| 1.4234 | 1.77757 | 0.00000 |
| 1.4626 | 1.77690 | 0.00000 |
| 1.5018 | 1.77623 | 0.00000 |
| 1.5410 | 1.77556 | 0.00000 |
| 1.5802 | 1.77489 | 0.00000 |
| 1.6194 | 1.77421 | 0.00000 |
| 1.6586 | 1.77353 | 0.00000 |
| 1.6978 | 1.77285 | 0.00000 |
| 1.7370 | 1.77215 | 0.00000 |
| 1.7762 | 1.77146 | 0.00000 |
| 1.8154 | 1.77075 | 0.00000 |
| 1.8546 | 1.77004 | 0.00000 |
| 1.8938 | 1.76931 | 0.00000 |
| 1.9330 | 1.76858 | 0.00000 |
| 1.9722 | 1.76784 | 0.00000 |
| 2.0114 | 1.76708 | 0.00000 |
| 2.0506 | 1.76631 | 0.00000 |
| 2.0898 | 1.76553 | 0.00000 |
| 2.1290 | 1.76474 | 0.00000 |
| 2.1682 | 1.76394 | 0.00000 |
| 2.1878 | 1.76353 | 0.00000 |
Sampled data (94 points total). Click "Download Full CSV" for complete data.
Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.