Optical constants (n, k) of H-LAF3B(CDGM), covering 0.36 – 2.19 μm wavelength range.
| Wavelength (μm) | n | k |
|---|---|---|
| 0.3650 | 1.78684 | 0.00000 |
| 0.4042 | 1.77307 | 0.00000 |
| 0.4434 | 1.76336 | 0.00000 |
| 0.4826 | 1.75619 | 0.00000 |
| 0.5218 | 1.75072 | 0.00000 |
| 0.5610 | 1.74642 | 0.00000 |
| 0.6002 | 1.74296 | 0.00000 |
| 0.6394 | 1.74013 | 0.00000 |
| 0.6786 | 1.73777 | 0.00000 |
| 0.7178 | 1.73578 | 0.00000 |
| 0.7570 | 1.73406 | 0.00000 |
| 0.7962 | 1.73257 | 0.00000 |
| 0.8354 | 1.73126 | 0.00000 |
| 0.8746 | 1.73009 | 0.00000 |
| 0.9138 | 1.72904 | 0.00000 |
| 0.9530 | 1.72809 | 0.00000 |
| 0.9922 | 1.72722 | 0.00000 |
| 1.0314 | 1.72641 | 0.00000 |
| 1.0706 | 1.72565 | 0.00000 |
| 1.1098 | 1.72495 | 0.00000 |
| 1.1490 | 1.72428 | 0.00000 |
| 1.1882 | 1.72364 | 0.00000 |
| 1.2274 | 1.72303 | 0.00000 |
| 1.2666 | 1.72244 | 0.00000 |
| 1.3058 | 1.72187 | 0.00000 |
| 1.3450 | 1.72131 | 0.00000 |
| 1.3842 | 1.72077 | 0.00000 |
| 1.4234 | 1.72023 | 0.00000 |
| 1.4626 | 1.71970 | 0.00000 |
| 1.5018 | 1.71918 | 0.00000 |
| 1.5410 | 1.71866 | 0.00000 |
| 1.5802 | 1.71815 | 0.00000 |
| 1.6194 | 1.71763 | 0.00000 |
| 1.6586 | 1.71712 | 0.00000 |
| 1.6978 | 1.71661 | 0.00000 |
| 1.7370 | 1.71609 | 0.00000 |
| 1.7762 | 1.71557 | 0.00000 |
| 1.8154 | 1.71505 | 0.00000 |
| 1.8546 | 1.71452 | 0.00000 |
| 1.8938 | 1.71399 | 0.00000 |
| 1.9330 | 1.71346 | 0.00000 |
| 1.9722 | 1.71292 | 0.00000 |
| 2.0114 | 1.71237 | 0.00000 |
| 2.0506 | 1.71182 | 0.00000 |
| 2.0898 | 1.71126 | 0.00000 |
| 2.1290 | 1.71069 | 0.00000 |
| 2.1682 | 1.71011 | 0.00000 |
| 2.1878 | 1.70982 | 0.00000 |