glass SF5 Refractive Index

Optical constants (n, k) of glass SF5, covering 0.37 – 2.18 μm wavelength range.

Range 0.370 – 2.180 μm
Data Points 86

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 1.6691
k = 0.0000
589.3 nm (Na-D)
n = 1.6732
k = 0.0000
532 nm
n = 1.6784
k = 0.0000
1550 nm (Telecom)
n = 1.6423
k = 0.0000

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.37001.728650.00000
0.41261.707900.00000
0.45521.694550.00000
0.49781.685240.00000
0.54041.678410.00000
0.58301.673190.00000
0.62561.669090.00000
0.66821.665780.00000
0.71081.663050.00000
0.75341.660760.00000
0.79601.658800.00000
0.83861.657100.00000
0.88121.655610.00000
0.92381.654280.00000
0.96641.653090.00000
1.00901.652000.00000
1.05161.650990.00000
1.09421.650060.00000
1.13681.649180.00000
1.17941.648350.00000
1.22201.647560.00000
1.26461.646810.00000
1.30721.646070.00000
1.34981.645360.00000
1.39241.644660.00000
1.43501.643980.00000
1.47761.643300.00000
1.52021.642640.00000
1.56281.641970.00000
1.60541.641310.00000
1.64801.640650.00000
1.69061.639990.00000
1.73321.639330.00000
1.77581.638660.00000
1.81841.637990.00000
1.86101.637310.00000
1.90361.636620.00000
1.94621.635930.00000
1.98881.635230.00000
2.03141.634520.00000
2.07401.633810.00000
2.11661.633080.00000
2.15921.632340.00000
2.18051.631970.00000

Sampled data (86 points total). Click "Download Full CSV" for complete data.

Related Materials (Popular)

Need to measure glass SF5 thin film thickness?

Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.