Optical constants (n, k) of F8(LZOS), covering 0.36 – 1.97 μm wavelength range.
| Wavelength (μm) | n | k |
|---|---|---|
| 0.3650 | 1.67288 | 0.00000 |
| 0.4047 | 1.65661 | 0.00000 |
| 0.4358 | 1.64766 | 0.00000 |
| 0.4800 | 1.63843 | 0.00000 |
| 0.4861 | 1.63738 | 0.00000 |
| 0.4880 | 1.63715 | 0.00000 |
| 0.5140 | 1.63354 | 0.00000 |
| 0.5208 | 1.63260 | 0.00000 |
| 0.5300 | 1.63133 | 0.00000 |
| 0.5461 | 1.62911 | 0.00000 |
| 0.5682 | 1.62689 | 0.00000 |
| 0.5876 | 1.62495 | 0.00000 |
| 0.5893 | 1.62480 | 0.00000 |
| 0.6328 | 1.62140 | 0.00000 |
| 0.6439 | 1.62061 | 0.00000 |
| 0.6471 | 1.62040 | 0.00000 |
| 0.6563 | 1.61981 | 0.00000 |
| 0.6943 | 1.61762 | 0.00000 |
| 0.7065 | 1.61697 | 0.00000 |
| 0.7682 | 1.61434 | 0.00000 |
| 0.8521 | 1.61130 | 0.00000 |
| 0.8900 | 1.61019 | 0.00000 |
| 1.0139 | 1.60730 | 0.00000 |
| 1.0600 | 1.60642 | 0.00000 |
| 1.1286 | 1.60519 | 0.00000 |
| 1.3951 | 1.60132 | 0.00000 |
| 1.5296 | 1.59964 | 0.00000 |
| 1.8131 | 1.59614 | 0.00000 |
| 1.9701 | 1.59419 | 0.00000 |
Sampled data (29 points total). Click "Download Full CSV" for complete data.
Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.