CsPbBr3 (e) Refractive Index

Optical constants (n, k) of CsPbBr3 (e), covering 0.50 – 0.95 μm wavelength range.

Range 0.500 – 0.949 μm
Data Points 450

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 2.0290
k = 0.0000
589.3 nm (Na-D)
n = 2.0505
k = 0.0000
532 nm
n = 2.0866
k = 0.0000

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.50002.112500.00000
0.51102.103050.00000
0.52202.094190.00000
0.53302.085870.00000
0.54402.078060.00000
0.55502.070700.00000
0.56602.063760.00000
0.57702.057220.00000
0.58802.051050.00000
0.59902.045210.00000
0.61002.039680.00000
0.62102.034450.00000
0.63202.029480.00000
0.64302.024770.00000
0.65402.020290.00000
0.66502.016040.00000
0.67602.011990.00000
0.68702.008130.00000
0.69802.004460.00000
0.70902.000950.00000
0.72001.997600.00000
0.73101.994410.00000
0.74201.991350.00000
0.75301.988430.00000
0.76401.985630.00000
0.77501.982950.00000
0.78601.980380.00000
0.79701.977920.00000
0.80801.975560.00000
0.81901.973290.00000
0.83001.971120.00000
0.84101.969020.00000
0.85201.967010.00000
0.86301.965070.00000
0.87401.963210.00000
0.88501.961420.00000
0.89601.959690.00000
0.90701.958020.00000
0.91801.956420.00000
0.92901.954870.00000
0.94001.953370.00000
0.94901.952180.00000

Sampled data (450 points total). Click "Download Full CSV" for complete data.

Related Materials (Other)

Need to measure CsPbBr3 (e) thin film thickness?

Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.