CsBr(CRYSTRAN) Refractive Index

Optical constants (n, k) of CsBr(CRYSTRAN), covering 0.50 – 2.00 μm wavelength range.

Range 0.500 – 2.000 μm
Data Points 3

Optical Constants at Key Wavelengths

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.50001.708960.00000
1.00001.677930.00000
2.00001.670610.00000

Sampled data (3 points total). Click "Download Full CSV" for complete data.

Notes

Caesium Bromide is grown by sealed ampoule Stockbarger technique. CsBr is a soft pliable material.
IUPAC International Union of Pure and applied Chemistry recommends the spelling as Cesium. UK Useage is Caesium.
Solubility has historically been quoted as 124g/100mL at 25°C but Crystran Ltd tests 2021 have found this to be inaccurate.

REFERENCES:

(1) Handbook Optical Constants, ed Palik, V3, ISBN 0-12-544423-0

(2) Mitsuishi et al., J Opt Soc. Am. V52, p14, 1962

(3) Kelly, Bureau of Mines Bulletin, No371, p51, 1934

(4) S.Ballard et al; J.Opt.Soc.Am. Vol42, p684, 1952

(5) H.H.Li; J.Phys. Chem. Ref. Data. Vol 5, No 2. 1976

(6) K.Matthews. Crystran Ltd Test Data 2021

References

Related Materials (Specs)

Need to measure CsBr(CRYSTRAN) thin film thickness?

Acuitik film thickness measurement systems offer sub-nanometer non-contact precision.