CH3NH3PbCl3 Refractive Index

Optical constants (n, k) of CH3NH3PbCl3, covering 0.20 – 2.20 μm wavelength range.

Range 0.200 – 2.200 μm
Data Points 2001

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 1.9077
k = 0.0000
589.3 nm (Na-D)
n = 1.9238
k = 0.0000
532 nm
n = 1.9549
k = 0.0000
1550 nm (Telecom)
n = 1.8395
k = 0.0000

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.20001.753470.60363
0.25001.933020.73262
0.30002.142030.33843
0.35002.062160.24765
0.40002.287660.59129
0.45002.061340.00000
0.50001.982010.00000
0.55001.943300.00000
0.60001.919260.00000
0.65001.902730.00000
0.70001.890680.00000
0.75001.881530.00000
0.80001.874370.00000
0.85001.868640.00000
0.90001.863970.00000
0.95001.860090.00000
1.00001.856840.00000
1.05001.854070.00000
1.10001.851690.00000
1.15001.849630.00000
1.20001.847830.00000
1.25001.846240.00000
1.30001.844830.00000
1.35001.843560.00001
1.40001.842430.00000
1.45001.841390.00000
1.50001.840440.00000
1.55001.839540.00003
1.60001.838810.00007
1.65001.838070.00004
1.70001.837370.00003
1.75001.836700.00002
1.80001.836050.00002
1.85001.835430.00002
1.90001.834810.00001
1.95001.834160.00003
2.00001.833460.00006
2.05001.832570.00025
2.10001.831890.00088
2.15001.831590.00157
2.20001.831640.00214

Sampled data (2001 points total). Click "Download Full CSV" for complete data.