CaCO3-o(CRYSTRAN) (o) Refractive Index

Optical constants (n, k) of CaCO3-o(CRYSTRAN) (o), covering 0.20 – 2.10 μm wavelength range.

Range 0.200 – 2.100 μm
Data Points 12

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 1.6550
k = 0.0000

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.20001.902800.00003
0.30001.719600.00000
0.41001.680100.00000
0.51001.665300.00000
0.64001.655000.00000
0.71001.652100.00000
0.80001.648700.00000
0.91001.645800.00000
1.04001.642800.00000
1.50001.634600.00000
1.91001.627000.00000
2.10001.622000.00000

Sampled data (12 points total). Click "Download Full CSV" for complete data.

Notes

Calcite, or Iceland Spar, is a strongly birefringent material and is used for polarisers and retardation plates. Calcite is often mined naturally. Crystran Ltd has a stock of small calcite "rhombs" of good clear optical quality. Calcite cuts and polishes well.



CLEAVEAGE PLANE:

There can be confusion in the definition of the cleavage plane in calcite. Conventionally this has always been referred to as {10-11} but recent papers on AFM studies use {10-14}. Calcite cleaves between the bonds of the CO3 groups (in the CO3 layer). The CO3 group are offset relative to each other and inclined to the c axis giving 3 cleavage directions defining a rhomb. Following the {10-11} nomenclature the unit cell requires ¼ the length of the c axis as measured from XRD (on a dimension 4 times longer). The correct Miller indices are {10-14} but the conventional {10-11} is often used in order not to confuse and for easier comparison. (1)



REFERENCES:

1. Private Communication. J.A.Elliott. Dept. Materials Science, University of Cambridge. 2011

2. Crystallography - LINK to:
Practical Crystal Measurement. A.E.H.Tutton, Vol2, page 1329

3. Linear Thermal Expansion of Calcite - Link to: Mineral Society of America, Linear Thermal Expansion of Calcite.



WEBLINKS:

http://webmineral.com/data/Calcite.shtml - Has further information regarding Calcite.



Optical data are for ordinary ray (o).