AuAl2 Refractive Index

Optical constants (n, k) of AuAl2, covering 0.30 – 1.32 μm wavelength range.

Range 0.300 – 1.320 μm
Data Points 35

Optical Constants at Key Wavelengths

632.8 nm (He-Ne)
n = 1.1170
k = 1.7170
589.3 nm (Na-D)
n = 1.1870
k = 1.5660
532 nm
n = 1.2750
k = 1.4070

n, k Dispersion Curves

Data Table (Sampled)

Wavelength (μm)nk
0.30002.058001.49900
0.33002.084001.72200
0.36002.042001.86300
0.39001.842001.87200
0.42001.644001.78500
0.45001.430001.63900
0.48001.350001.50300
0.51001.289001.40600
0.54001.275001.40700
0.57001.235001.47000
0.60001.187001.56600
0.63001.117001.71700
0.66001.057001.87400
0.69001.007002.04200
0.72000.970002.21000
0.75000.944002.37200
0.78000.930002.53200
0.81000.921002.68600
0.84000.914002.83600
0.87000.907002.98500
0.90000.900003.13000
0.93000.899003.27300
0.96000.901003.41200
0.99000.905003.54800
1.02000.919003.68200
1.05000.936003.81400
1.08000.953003.94600
1.11000.971004.07500
1.14000.993004.20100
1.17001.020004.32500
1.20001.049004.44600
1.23001.077004.56200
1.26001.107004.67600
1.29001.141004.78900
1.32001.178004.89800